Krishnan, Midhun (2021) Functional Outcome of Shaft of Humerus Fractures Managed Surgically by Dynamic Compression Plating Technique. Journal of Pharmaceutical Research International, 33 (49B). pp. 101-104. ISSN 2456-9119
4100-Article Text-5970-1-10-20221006.pdf - Published Version
Download (260kB)
Abstract
The study analyzed 20 cases of fracture shaft of hummers treated with Dynamic Compression Plate. There was a male preponderance in our study 17 (85%). Almost Also 13% of patients treated by functional bracing end up with cosmetically unacceptable angulation of>15%, whereas all operative procedures achieve good alignment of the fractured bone was observed. The rate of union in Plate osteosynthesis is 93% and the time of union is 16 - 20 weeks, and more than 90% united in 18 weeks and 7% went for non union.
Item Type: | Article |
---|---|
Subjects: | Pacific Library > Medical Science |
Depositing User: | Unnamed user with email support@pacificlibrary.org |
Date Deposited: | 13 Apr 2023 05:49 |
Last Modified: | 03 Sep 2024 05:51 |
URI: | http://editor.classicopenlibrary.com/id/eprint/313 |